Eaton Tripp Lite Series 1.4kW Single-Phase Switched Automatic Transfer Switch PDU, 2 120V 5-15P 15A Inputs, 8 5-15R Outputs, 1U, TAA

Product Number: SYNX1814151
$580.94
Loading...
Ships Free - This items ships free with your order
Delivered by Tue 12/3 Wed 12/4 - This is an estimated delivery timeline
Non Returnable - This is a non returnable item
Loading...

Product Description

Eaton Tripp Lite Series 1.4kW Single-Phase Switched Automatic Transfer Switch PDU, 2 120V 5-15P 15A Inputs, 8 5-15R Outputs, 1U, TAA
2 12ft Cords, 1U Rack-Mount, TAA"
Description:
Tripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. The built-in Java-free HTML5-based LX Platform interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, BOOTP and NTP. Switched PDU features include individually controllable output receptacles. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability.
More from the Manufacturer
  • Single phase 15A 120V Auto Transfer Switch / ATS PDU
  • Built-in Java-free LX Platform interface for 24/7 remote access
  • Enables redundant A/B power option for single-corded network devices
  • Separate primary & secondary inputs connect to any two compatible power sources
  • 1U horizontal rackmount; 2 NEMA 5-15P inputs; 8 NEMA 5-15R outlets
  • Individually switched outlets; Two digit visual current meter
  • Federal Trade Agreements Act / TAA Compliant for GSA Schedule purchases
  • PDU provides active metering enabling energy optimization and circuit protection
  • With a built-in digital current meter avoid potential overloads via switched PDUs
  • NEMA 5-15R receptacle type to ensure maximum productivity with added feasibility
  • NEMA 5-15P plug/connector type for reliable, productive connectivity and optimal power output
  • 120 V AC input voltage for optimal performance with maximum usability
  • 120 V AC output voltage for better reliance and maximum usability

Product Specifications

  • Brand Name
    Tripp Lite by Eaton
  • Certifications & Standards
    60950 Class A RoHS compliant
  • Country of Origin
    Taiwan
  • Depth
    14.5"
  • Environmentally Friendly
    Yes
  • Height
    1.8"
  • Input Voltage
    120 V AC
  • Limited Warranty
    2 Year
  • Management
    Integrated Automatic Transfer Switch (ATS) allows PDU to operate from secondary input source when primary input fails Sequential outlet power-on prevents inrush-related equipment interaction on startup Programmable or real-time outlet power control via web/network monitoring and control card
  • Manufacturer Part Number
    PDUMH15ATNET
  • Mount Type
    Rack-mountable
  • Mounting Orientation
    Vertical
  • Output Voltage
    120 V AC
  • Package Contents
    PDUMH15ATNET PDU Switched ATS 120V 15A 8 Outlet PDU with attached 5-15P input power cord Detachable C13 to NEMA 5-15P 12 ft/3.6m power cord for optional secondary input User manuals with warranty information
  • Plug/Connector Detail
    2 x NEMA 5-15P
  • Plug/Connector Type
    NEMA 5-15P
  • Power Rating
    1.80 kVA
  • Power Rating (VA)
    1800 VA
  • Product Color
    Black
  • Product Model
    PDUMH15ATNET
  • Product Name
    PDUMH15ATNET PDU Switched ATS 120V 15A 8 Outlet
  • Product Type
    PDU
  • Rack Height
    1U
  • Receptacle Detail
    8 x NEMA 5-15R
  • Receptacle Type
    NEMA 5-15R
  • Width
    1.8"