APC NetShelter Rack PDU Advanced, Switched Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 48 Outlets, IEC309
Product Number:
ETLZ1072294032
Sold Out
This product is sold out and we do not know when we will be getting another shipment. We apologize for any inconvenience this may cause.
Check similar items above to see if a replacement product is available.
Product Description
APC NetShelter Rack PDU Advanced, Switched Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 48 Outlets, IEC309
Switched - IEC 60309 30A 3P+N+PE - 24 x IEC 60320 C13/C15/C19/C21, 24 x IEC 60320 C13/C15 - 415 V, 480 V - Network (RJ-45) - 5.91 ft Cord Length - 0U - Rack
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. Outlet and PDU level power metering for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparalleled deployment flexibility. Maximum outlet density with 48 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.
- Input: 3PH, 530P6
- Outlets: (24) C13/C15/C19/C21, (24) C13/C15
- Full-featured network management capability
- Interactive LCD display
- Active power measurements (volts, amps, kW, kWh)
- 3-year APC warranty
- PDU allows power to be more efficiently distributed and controlled
- With a built-in digital current meter avoid potential overloads via switched PDUs
- IEC 60320 C13/C15/C19/C21 receptacle type to ensure maximum productivity with added feasibility
- Three Phase phase PDU provides dependable power output with maximum efficiency
- IEC 60309 30A 3P+N+PE plug/connector type for efficient connectivity and feasible power output
- 415 V input voltage for optimal performance with maximum usability
- 240 V AC output voltage for better reliance and maximum usability
Loading...
Product Specifications
-
Additional Warranty Information3 years repair or replace
-
Brand NameAPC by Schneider Electric
-
Certifications & StandardsUKCA Compliance TAA Compliance BAA Compliance
-
Cord Length5.91 ft
-
Country of OriginIndia
-
Depth3"
-
EU RoHS Declaration URLhttps://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=552063000&lang=en-us
-
End of Life Manual Availabilityhttps://download.schneider-electric.com/files?p_enDocType=Circularity+Profile&p_Doc_Ref=ENVEOLI1612033_EN
-
Environmental ComplianceRestriction of Hazardous Substances (RoHS)
-
Environmental Profile Availabilityhttps://download.schneider-electric.com/files?p_enDocType=Environmental+Disclosure&p_Doc_Ref=ENVPEP1612033_EN
-
Environmentally FriendlyYes
-
Form FactorRack
-
Height70.1"
-
Input Current30 A
-
Input Voltage415 V 480 V
-
Input Voltage Range200 V AC - 240 V AC 346 V AC - 415 V AC
-
Limited Warranty3 Year
-
Manufacturer Part NumberAPDU10350SM
-
Network (RJ-45)Yes
-
Output Voltage240 V AC
-
PhaseThree Phase
-
Plug/Connector TypeIEC 60309 30A 3P+N+PE
-
Power Rating (VA)17.30 kVA
-
Power Rating (Watt)17.30 kW
-
Product ColorBlack
-
Product LineNetShelter
-
Product NameNetShelter 48-Outlets PDU
-
Product Take Back ProgramNo
-
Product TypePDU
-
REACH Declaration URLhttps://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=exportPdfReach&pid=552063000&lang=en-us
-
REACH free of SVHCYes
-
Rack Height0U
-
Receptacle Detail24 x IEC 60320 C13/C15 24 x IEC 60320 C13/C15/C19/C21
-
Receptacle TypeIEC 60320 C13/C15 IEC 60320 C13/C15/C19/C21
-
RoHS Exemption Informationhttps://download.schneider-electric.com/files?p_enDocType=Declaration+of+Conformity+%28Sustainability%29&p_Doc_Ref=APDU10350SM_ROHS_DECLARATION&p_FileName=APDU10350SMKIT_ROHS_DECLARATION_US.pdf
-
WEEE StatementThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
-
Width2.2"